Top-Tier Standards: Fully compliant with UL 10D (Fire Protective Curtains) and UL 1784 (Air Leakage Tests for Door Assemblies).
Code Adherence: Meets rigorous NFPA 80 and IBC (International Building Code) standards.
High Endurance: Capable of providing up to 3 hours of fire protection, giving occupants valuable time to evacuate and first responders time to act.
Smart Integration: Seamlessly interfaces with existing building fire alarm systems for instant, fail-safe deployment.

The standard for protecting open concept designs. These flexible barriers deploy vertically to seal off atriums, stairwells, and large openings.
Best for: Atriums, corridors, and open-plan offices.
Rating: UL 10D, 1-3 Hour Protection.
Eliminate the need for enclosed elevator lobbies. These curtains deploy directly over elevator doors to prevent the shaft from acting as a chimney for smoke.
Best for: Hotels, high-rise office buildings, and hospitals.
Compliance: Meets IBC §3006.2 for hoistway protection.


A unique solution for sealing ceiling openings and skylights, preventing fire from traveling between floors through horizontal voids.
Best for: Escalators, skylights, and floor voids.
Designed to create a fire-rated enclosure without the need for corner posts. These accordion-style curtains can navigate curves and corners to seal off specific zones.
Best for: Reception desks, open staircases, and specialized retail zones.

Architects in the Upstate region choose our systems because they allow for:
Open Concept Atriums: Fulfill IBC 404.6 requirements without permanent walls.
Unobstructed Views: Maintain clean sightlines in lobbies and museums.
Space Efficiency: Remove the bulk of traditional fire doors in tight corridors

Local Expertise: Serving Greenville, Spartanburg, Anderson, and the surrounding Upstate region
Custom Fit: We work with your architectural plans to ensure a seamless fit.
Certified Installers: Our team is trained to install systems that meet strict manufacturer and code requirements.
Yes. Many of our models, such as the Fire Rated Smoke Curtain SD, are specifically tested to UL 1784 standards to restrict the movement of smoke, which is often more dangerous than the fire itself.
In many applications, yes. They are an approved alternative for fire-rated barriers in specific code scenarios, such as elevator hoistways and atrium separation. Always consult with your local authority having jurisdiction (AHJ).
Our systems are designed with "fail-safe" gravity deployment or battery backups, ensuring the curtain descends to the operational position even during a total power failure.